TEXT OF RULE 19NYCRR Part 1264 Subchapter C of Chapter XXXIII of
Title 19 of the Official Compilation of Codes, Rules and Regulations
of the State of New York is amended by adding a new Part 1264
to read as follows: Part 1264 IDENTIFICATION OF BUILDINGS UTILIZING TRUSS TYPE CONSTRUCTION 1264.1 Introduction. Section 382-a
of the Executive Law provides that commercial and industrial
buildings and structures
that utilize truss type construction
shall be marked by a sign or symbol that informs persons conducting fire
control and other emergency operations of the existence of
truss construction. Section
382-a further directs the State Fire Prevention and Building Code Council
to promulgate rules and regulations it deems necessary to
carry into effect the
provisions of the statute. This Part establishes certain requirements pertaining
to the identification of buildings and structures that utilize truss type
construction. 1264.2 Enforcement. (a) Subdivision 4 of section
382-a of the Executive Law directs local governments to provide
for enforcement of the statute. Enforcement
of section
382-a of the Executive Law shall include enforcement of the provisions
of this Part. A fee of fifty dollars shall be paid by
the
owner of a building
with
truss type construction to the authority having jurisdiction for enforcement
of section
382-a of the Executive Law prior to the issuance of a building permit. (b) This Part shall not apply within a city with
a population of one million or more persons. 1264.3 Definition. For the purposes of this Part, truss type
construction shall mean a fabricated structure of wood or steel,
made up of a series of members connected at their ends to form
a series of triangles to span a distance greater than would be
possible with any of the individual members on their own. Truss
type construction shall not include:
(1) individual wind or seismic bracing components which form
triangles when diagonally connected to the main structural system;
and (2) structural components that
utilize solid plate web members. 1264.4 Identification of truss type construction. (a) Truss type
construction shall be identified by a sign or signs in accordance
with the provisions of this Part. (b) Signs shall be affixed where a building or a portion thereof
is classified as Group A, B, E, F, H, I, M, or S occupancy, and
in hotels and motels classified as Group R-1 or R-2 occupancy,
in accordance with the provisions for the classification of buildings
set forth in chapter 3 of the Building Code of New York State
(see 19 NYCRR Part 1221). (c) Signs shall be provided in newly
constructed buildings that utilize
truss type construction and in
existing buildings where an addition
that extends
or increases the floor area of the building utilizes truss type construction.
Signs shall be affixed prior to the issuance of a certificate of occupancy
or a certificate of compliance. (d) Signs identifying the existence
of truss construction shall consist
of a circle 6 inches (152.4 mm)
in diameter, with a stroke width
of ½ inch
(12.7 mm). The sign background shall be reflective white in color. The circle
and contents shall be reflective red in color, conforming to Pantone matching
system (PMS) #187. Where a sign is directly applied to a door or sidelight,
it may be a permanent non-fading sticker or decal. Signs not directly applied
to doors or sidelights shall be of sturdy, non-fading, weather resistant material. (e) Signs identifying the existence
of truss construction shall contain
the roman alphanumeric designation
of the construction type of the
building, in
accordance with the provisions for the classification of types of construction
set forth in section 602 of the Building Code of New York State (see 19 NYCRR
Part 1221), and an alphabetic designation for the structural components that
are of truss construction, as follows: “
F” shall mean floor framing, including girders and beams “
R” shall mean roof framing “
FR” shall mean floor and roof framing
The construction type designation shall be placed at the twelve o’clock
position over the structural component designation, which shall be placed at
the six o’clock position. (f) Signs identifying the existence
of truss construction shall be
affixed in the locations specified
in Table I-1264. TABLE I-1264 TRUSS IDENTIFICATION SIGN LOCATIONS
|